Paramtents

  • Working Power AC220V±15%,overall power consumption less than 2W

  • Operating temperature 0℃~55℃

  • Working humidity ≤95%RH(when 40℃)

  • Response time Not more than 30S(methane)

  • preheating time 120S

  • Sensor life The service life under normal atmospheric environment is 5 years

  • Alarm set point1 Natural gas (methane):10%LEL

  • Alarm set point2 Carbon monoxide(CO):240×10-6

  • Packing quantity 24set/carton

Packging & Delivery

  • 41cm x 33cm x 44cm
  • Min Order21 carton

Briefing

JTQ-BH-PH04A/TM Independent combustible gas detector

Detailed

JTQ-BH-PH04A/TM Independent combustible gas detector, is used in domestic kitchens who using natural gas. When an alarm occurs, the detector sends out sound and light alarm signals, and controls to close the valve and cut off the gas supply, so as to prevent gas leakage and explosion accidents, personal poisoning accidents and fire accidents. 

Adopt advanced semiconductor gas sensor with high sensitivity, stable performance, long service life and strong anti-interference ability;Anti-oil structure design;Built-in "black box data storage" patented technology;

Executive standard:GB15322.2-2003

1. Working Power:AC220V±15%,the machine power consumption is less than 2W;

2、Working Temperature:0℃~55℃;

3. Working Humidity:≤95%RH(when 40℃);

4. Response Time:No more than 30S(methane);

5. Preheating Time:120S;

6. Sensor life:The service life under normal atmospheric environment is 5 years;

7. Alarm set point:

Natural gas (methane):10%LEL;

Carbon monoxide(CO):240×10-6;

8. Linkage output mode:Low pressure dc solenoid valve.